Truth Table to Schematic Diagram Converter
Step 1 Truth Table to Diagram converter can be evoked from Schematic Editor| Tools| Convert Truth Table to Diagram
Step 2 Convert Truth table to Diagram window appears, set the truth table properties as shown in figure below and click on Next Button.

Step 3 Click on Next Button will prompts you to Edit Truth Table window where you can assign the output values for the given input as shown in figure below.

Step 4 Click on Next button to proceed to Process truth table window where you can set placement parameters, placement area and placement topologies.

Step 5 Click on Finish button. The diagram will get tagged to the cursor, place the diagram in the suitable position on work space.

Checking the functionality of the diagram
Step 1 Evoke Mixed Mode Simulator from Schematic Editor |Preferences.
Step 2 Assign clock patterns on input nets by using clock generator patterns. You can evoke clock generator from Tools| Instruments
|preset logic state
|Clock Generator
.

Step 3 Place the wave form markers on input and output nets from Tools| Instruments
|Set wave form contents
|logic wave form
.

Step 4 Preprocess the circuit from, Simulation tools| Preprocess
.
Step 5 Evoke analysis from, Simulation tools| Analysis
and set the parameters for Transient Analysis.
Step 6 Run the analysis and compare the output wave form with the predefined truth table.